Index |
Device |
Function |
1 |
Down Speed Control
|
Controls horn rate
of descent. Return rate is fixed. |
2 |
WELD TIME |
Control Set duration
of ultrasonic (0.1 to 4 seconds). |
3 |
HOLD TIME |
Control Set duration
of clamping pressure on part after exposure to ultrasonic (.05 to 3 seconds). |
4 |
Pressure Indicator |
Indicates pressure
applied to air cylinder |
5 |
Pressure Regulator |
Adjusts pressure
to air cylinder. |
6 |
Loading Meter |
Indicates ultrasonic
power |
7 |
Overload Indicator/Reset
Switch |
Indicates power
supply overload. Also resets overload indicator when optional protection
indicator module is on the latched mode. |
8 |
ON-OFF |
Switch Applies
main power to system |
9 |
HORN DOWN/TEST
Ultrasonic switch
|
Horn Down position.
Lowers Horn when one palm button is depressed. TEST ULTRASONIC position:
Energizes power supply for tuning the system. |
10 |
Dynamic Trigger
(TRIGGER PRESSURE)Control |
Controls Pre-clamp
pressure prior to ultrasonic energy being applied. |
11 |
Pilot Light |
Indicates when
main power is on or off. |
12 |
Tuning Control |
Adjustment for
optimizing power supply performance. |
13 |
Anti Tie-Down Palm
(START) Buttons |
Activates the system
when pressed simultaneously. |
14 |
Emergency
STOP TWIST TO RESET Button |
Interrupts
welding cycle and causes horn to retract. Pull out to reset. |
15 |
Column
Clamp |
Locks
head assembly in position |
16 |
Elevator
Knob |
Permits
vertical movement for gross height adjustment and is counter balanced. |
17 |
Fuse |
Overload
protection |
18 |
Mechanical
Stop |
Controls
depth of weld and acts as safety device to protect horn and fixture. |
19 |
Base Cable Connector |
Connects actuator
to base assembly. |
20 |
Chrome
Plated Column |
Provides
smooth, easy head height and swivel adjustment |